GU ELECTRIC — Beyond the CabinetGU ELECTRIC — Beyond the Cabinet Get a quote
B U I L D T O D R A W I N G Industrial socket box, front view (door closed; miniature circuit breaker viewing window on the left of the door face, five industrial sockets arranged in a row along the lower edge)
PRODUCT — 02 · Low-Voltage Distribution & Assemblies

Maintenance power boxes

A safe power island on site
Model GU-SOB · 2–8 CEE socket circuits · ground fault protection per circuit · MOQ 1 unit
Maintenance power boxes give workshops, warehouses and outdoor maintenance points a safe temporary power take-off: CEE industrial sockets (keyed against mismating, mechanically retained) with independent ground fault protection on every circuit, and mixed 380V and 220V output so drills, welders, lighting and battery tools can be plugged in as needed. Enclosure is wall-mount or wheeled portable, IP54 as standard and IP65 for washdown areas; ground fault trip current is 30 mA, and a fault on a socket circuit trips only that circuit so maintenance work continues.
  • Sockets: CEE industrial sockets (3P+E / 2P+E), keyed against mismating, mechanically retained, IP54 cover
  • Protection: independent ground fault (30 mA) + circuit breaker per circuit; a fault trips only that circuit
  • Mixed output: 380V (16/32 A) and 220V (16 A) arranged as required
  • Configuration: wall-mount / portable (wheels and handle)
  • Enclosure: cold-rolled steel or stainless steel, IP54 / IP65 (washdown areas)
2–8 circuitsSocket circuits
30 mAGround fault tripping per circuit
IP54–IP65IP rating
1 unitMOQ 1 unit · ≥5 recommended for volume production
01 — SPECIFICATION

Specifications

The table below covers 80% of factory distribution room cases. Anything outside it we can still build — those are engineered items, quoted separately, with an indicative price the same day.

Enclosure typeWall-mount / portable (wheels + handle, optional cable reel)
Standard dimensions (W×H×D)400×500×200 to 600×800×250 mm, custom builds available
Enclosure construction1.5 mm cold-rolled steel or 304 stainless steel (corrosive environments)
IP ratingIP54 standard / IP65 (washdown areas), sockets with splash covers
Door and lockTop-hinged door (rain-shedding); no need to open it fully to plug in
Cable entryBottom cable gland entry; portable units supplied with rubber-sheathed cable
Rated voltageAC 380V / 220V, 50 Hz
main breakerIsolator + circuit breaker (≤63 A)
Socket specificationsCEE 380V 16/32 A (3P+E), CEE 220V 16 A (2P+E)
Branch circuit protectionDedicated breaker + 30 mA residual current module per circuit; trips that circuit only
IndicationPower indicator; optional run indicator per circuit
Equipotential bondingEnclosure grounding terminal clearly marked; PE bonded reliably to the enclosure
Component brandsChint / Schneider / ABB sockets and breakers; customer-supplied components accepted for factory fit
Workshop maintenance typeWall-mounted along the wall; one unit every 15–20 m in the mechanical repair area
Warehouse and logistics typePower takeoff for charging and packaging equipment, mainly 220V
Outdoor site typePortable with rubber-sheathed cable, IP65
Production line workstation typeFixed installation beside the workstation; power takeoff for power tools and test instruments
Dock and wharf typeStainless steel enclosure with salt-spray protection; fully protected CEE
Assembly standardGB/T 7251.1 / IEC 61439-1; sockets to GB/T 3828 / IEC 60309
Ground fault verificationVerify residual current tripping circuit by circuit with the test button and record results
Routine tests (every unit)Insulation resistance, dielectric withstand, circuit-by-circuit energization and residual current tripping
Temperature riseSocket terminals and breaker connections ≤70 K
Documents with shipmentSystem diagram, terminal schedule, BOM, test report
02 — CONFIGURATOR

Five steps to specify your run

A configuration summary is generated as you go. It travels with your inquiry, saving a round of confirmation.

01Number of socket circuits
02Voltage configuration
03Mounting type
04Enclosure material
05Options (multiple)
03 — CRAFT

Build details

Systems have been in service for decades, and the failure points are always the same few: poor busbar contact, water ingress at the door seal, high temperature rise in the correction cabinet, and mis-phased outgoing feeders. The six hard rules below are written for exactly these points — every cabinet can be traced to them.

Independent per circuit

One-to-one ground fault protection

Independent ground fault module per circuit: a fault on one circuit trips only that circuit, the rest keep running. A single main ground fault device costs less, but one trip shuts everything down — the last thing you want on a maintenance site.

Splash guard

No exposed sockets

Every socket gets a splash guard, so rain and dust stay out through the plug-in gap. Interlocked guard-and-socket designs are preferred, with no reduction in mis-insertion protection.

Top-hinged door

Water stays out

Outdoor doors use top hinges: rain runs off the door instead of into the box; the door gasket seals to IP54 or better.

Continuous grounding

PE first

Enclosure grounding terminals are labeled and placed up front, and the PE-to-enclosure bond is continuity-tested on every unit — on temporary power, the worst case is an energized enclosure nobody knows about.

Circuit-by-circuit verification

Ground fault test button pressed on every unit

Every ground fault module is factory-tested by pressing the test button, one by one, verified to trip at 30 mA with no compromise; both trip and no-trip results are recorded.

Mobile protection

Rubber cable + reel

Mobile units come with rubber-sheathed cable and a reel, so cable stays organized and off wet ground; the reel has a brake and locks as soon as it is pulled out.

04 — EVIDENCE

Photos & enclosure construction

Below are photos taken in our own shop — from the complete unit down to the internal busbars and secondary wiring. Every build detail can be checked item by item.

Industrial socket box, front view (door closed; miniature circuit breaker viewing window on the left of the door face, five industrial sockets arranged in a row along the lower edge)
Industrial socket box, front view (door closed; miniature circuit breaker viewing window on the left of the door face, five industrial sockets arranged in a row along the lower edge)
Industrial socket box, socket array on the door face (two miniature circuit breaker viewing windows in the upper row, five blue industrial sockets in a row in the lower row)
Industrial socket box, socket array on the door face (two miniature circuit breaker viewing windows in the upper row, five blue industrial sockets in a row in the lower row)
Stainless steel outdoor large distribution box with inner door · Photo 01
Stainless steel outdoor large distribution box with inner door · Photo 01
FRONT VIEW Power meter Status indication Channel base at the bottom · inter-cabinet busbars run through H 2200 W 800 / 1000 / 1200 IP54 standard IP65 optional Ue 400V ≤2000A Icw 30–65kA
Verifiable build checklist:2.0 mm seam-welded enclosure · diagonal ≤1.5 mm · busbar torqued to 30-40 N·m with witness marks · busbar joint temperature rise ≤70 K · segregated wiring compartments · CTs and meters in separate compartments · 60-80 μm coating · 2500 V/1 min withstand on every unit.

Image key: 01–05 are shop photos (the numbers match the shot list). The line drawing shows the front elevation of the enclosure; dimensions match the specification table above.

05 — APPLICATIONS

Where these cabinets go

These are the routine applications — we can talk scheme and configuration directly. For the industry view, see the industry pages.

Workshop maintenance bay

Power for power tools and test instruments, distributed along the wall.

Warehouse and packing area

Packaging machines and charging tools, mostly 220V.

Outdoor job site

Mobile power take-off, IP65 rain and dust protection.

Shipyard and dock

Stainless steel + salt-fog protection, fully guarded CEE.

Production line workstation

Fixed power take-off at the workstation — plug tools in and go.

Washdown bay

Food processing and livestock washdown environments — IP65, 30 mA ground fault protection on every circuit.

06 — TERMS

Commercial terms

Specification dated September 2026; quotations follow this.

Drawings & designFree
MOQ1 unit (5 or more recommended for production)
Production lead time15-25 days after drawing approval
on-time delivery98%
Warranty12 months
Loading portNingbo / Shanghai, China
Component brandsSchneider / ABB / Siemens / Chint
Factory visit & dispatch confirmationFactory visits welcome; finished-cabinet photos and video before dispatch
Capacity5,800+ units / year
07 — DOWNLOADS

Documents for your engineering team

Selection manual, outline dimensions and RFQ checklist — for the customer's electrical engineer. All three documents are being organized by product line; download links go live once complete.

PDFSelection and configuration manualTechnical highlights, specifications, typical solutions and commercial termsIn progress · pending
DXFCommon outline & cut-out dimensionsFront view / side view / foundation and cable entry cutoutsIn progress · pending
XLSRFQ data checklistInformation to confirm before quoting — fill in and send backIn progress · pending
08 — FAQ

Six questions procurement and electrical engineers ask most

How is a CEE socket different from a standard socket?

CEE industrial sockets have keyed slots that prevent mismating (different voltages use different pin configurations, so you can't plug into the wrong supply), mechanical retention (they don't work loose under vibration), and a high splash rating. Their plug/cycle life is an order of magnitude higher than residential sockets. This is the long-standing standard for industrial environments — don't use residential power strips on the shop floor.

What does 30 mA ground fault protection actually mean?

30 mA is the threshold for human safety: a ground fault above 30 mA trips in milliseconds, cutting power before a person is electrocuted. Each circuit on the maintenance box has its own 30 mA protection, so a fault on one circuit only shuts down that circuit — other workstations keep running.

How do I choose between portable and wall-mounted?

If the power take-off point is fixed, go wall-mounted (workshops, warehouses). If the work area moves (construction sites, shipyards, large-scale maintenance), go portable with wheels and rubber-sheathed cable. For portable units, add a cable reel — cables dragged on the ground and sitting in water are the number one cause of electrical shock on job sites.

Can I use it with a welding machine?

Manual welding machines can draw power from it without issue (size the socket and protection to the welder's input current). But the welder's own high inrush current can nuisance-trip the ground fault module — for welder circuits, specify a high-immunity ground fault device or a dedicated circuit, and state the application when ordering.

Can I add metering?

Yes: total metering (for billing) or branch-circuit metering (for internal cost allocation). The meter is supplied to the owner's or utility's specification; we provide the meter position and wiring.

Will condensation form outdoors in winter?

Yes — the day-night temperature swing is the main cause. For outdoor and cold-chain environments, specify an anti-condensation heater with thermostat control. No condensation inside the enclosure means no corrosion on components. The heater draws very little power and does not compromise the overall ingress protection.

09 — RELATED

Other cabinet types in the same main circuit

Related products use color-block placeholders for now (product photos not yet complete; they will be replaced together). Internal links will be filled in once live URLs are confirmed.

10 — RFQ

Send us the power take-off points and we'll configure the sockets to match

Send us your points and tool list (voltage / number of circuits / environment) and we'll provide a free socket box plan · quote within 24 hours. Direct from the source factory, MOQ 1 unit, 15–25 day lead time, 1-year warranty.

Email your inquiry WhatsApp: +86 186 5712 0011
GU ELECTRIC (Zhejiang Golden Unicorn) · 5,000 sqm workshop, Fengchuan Industrial Zone, Tonglu · 20 people · 5,800+ units per year
ISO 9001:2015 · CE(LVD+EMC) · CQC · IP65

When you write, include: single-line diagram or primary scheme, switch room layout, load list, and component brand requirements. You do not need complete drawings — capacity and cabinet type are enough to start.

Maintenance power box · MOQ 1 unit · 15–25 days Get a quote