Rittal-style enclosures
- Frame: welded 9-fold profile frame, high strength and rigidity, cabinet body resists deformation
- Modular grid: 25 mm modular cutouts, standard accessories such as mounting plates, DIN rails, and wire ducts interchange
- Baying: frame has baying holes, multiple cabinets bay side by side for flexible expansion
- Customization: size, door type, cutouts, and powder-coat color built to drawing
- Protection: IP54 standard / IP65 optional, door seam gasket
Specifications
The table below covers 80% of factory distribution room cases. Anything outside it we can still build — those are engineered items, quoted separately, with an indicative price the same day.
| Frame | Welded 9-fold profile frame, high cabinet strength and rigidity |
|---|---|
| Standard sizes (W×D×H) | 600×600×2000 / 800×600×2000 / 800×800×2000 / 1000×800×2000 mm, non-standard available |
| Modular | 25 mm modular cutouts, standard accessories such as mounting plates, DIN rails, and wire ducts interchange |
| Enclosure construction | Profile frame + cold-rolled steel door and side panels, removable for maintenance |
| Surface treatment | Degrease, derust, phosphate → electrostatic powder coating 60–80 μm, color specified (RAL 7035, etc.) |
| IP rating | IP54 standard / IP65 optional (door seam gasket) |
| Cabinet joining | Frame has baying holes, multiple cabinets bay side by side for flexible expansion |
| Door and lock | Single door / double door, flat lock or multi-point lock, optional transparent viewing window |
| Application | Distribution, control, network and server cabinets — internal layout configured by application |
|---|---|
| Mounting plate | Galvanized mounting plate, 25 mm adjustable pitch, components arranged in columns |
| Wire duct and DIN rail | Standard 35 mm DIN rail + wire duct, clean and serviceable wiring |
| Grounding | Frame and mounting plate grounding, ground continuity tested |
| Accessories interchangeable | DIN rails, wire ducts, mounting plates and other accessories interchangeable with European and US standard cabinets |
| Customization scope | Dimensions, door type, cutouts, powder coat color and internal layout built to drawing |
| control cabinets | Houses PLCs, VFDs and relays for equipment control |
|---|---|
| Distribution cabinet | Houses breakers and busbars for power distribution |
| Network / server cabinet | 19 in. mounting for network equipment and servers |
| Coupled assembly | Multiple cabinets coupled into a large assembled system |
| Operator console integration | Pairs with operator consoles and cantilever boxes for centralized control |
| Build to drawing | Built to customer drawings for dimensions, cutouts and structure |
| Reference standards | GB/T 7251.1 / IEC 61439-1 (assemblies); GB/T 19290 (structural dimensions for electrical equipment) |
|---|---|
| Modular standard | 25 mm modular grid, compliant with IEC 297 and related structural standards |
| IP rating | GB 4208 / IEC 60529, IP54 / IP65 |
| Insulation resistance | ≥1 MΩ (500V megohmmeter) |
| Power frequency withstand voltage | Main circuit 2500V / 1 min, control circuit 1500V / 1 min |
| Factory tests | Structural dimension check, ingress protection check, ground continuity, powered functional test |
| Documents with shipment | Structural drawing, cutout drawing, BOM with brand and model, test report, factory photos |
Five steps to specify your run
A configuration summary is generated as you go. It travels with your inquiry, saving a round of confirmation.
Build details
Systems have been in service for decades, and the failure points are always the same few: poor busbar contact, water ingress at the door seal, high temperature rise in the correction cabinet, and mis-phased outgoing feeders. The six hard rules below are written for exactly these points — every cabinet can be traced to them.
9-fold formed profile
The profile section is 9-fold formed, giving higher strength and better rigidity than ordinary square tube. A stable frame is what keeps doors and accessories aligned and serviceable over time.
Modular perforations
The uprights have 25 mm modular perforations, compatible with mounting plates, DIN rails and wire ducts. This is also the biggest difference between a Rittal-style cabinet and an ordinary welded cabinet — standardized and expandable.
Frame with bayed-cabinet holes
The frame has pre-drilled bayed-cabinet holes so multiple cabinets can be bayed side by side. Expansion doesn't require building a new cabinet — just bay it on.
Interchangeable accessories
The structure follows the modular pattern of European and US standard cabinets, so accessories such as DIN rails, wire ducts and mounting plates are interchangeable with standard cabinets. Sourcing spares for later maintenance won't leave you stuck.
Color specified to RAL
Electrostatic powder coating, with color specified to the RAL chart (common colors such as 7035). On batch engineering projects, what matters is consistent color.
Dimensions and structure to drawing
Dimensions, door type, cutouts and internal structure are all built to drawing. The value of a Rittal-style cabinet lies in the structural system, not in fixed dimensions.
Photos & enclosure construction
Below are photos taken in our own shop — from the complete unit down to the internal busbars and secondary wiring. Every build detail can be checked item by item.



Image key: 01–05 are shop photos (the numbers match the shot list). The line drawing shows the front elevation of the enclosure; dimensions match the specification table above.
Standard width: multiple angles
The standard width version is the regular-width build. Below are shop-floor photos taken from several angles around the enclosure, so you can review door fabrication, the coupling face and internal layout against your drawings.






This section shows shop-floor photos covering enclosure structure and door fabrication from multiple angles. The image numbers match the shot list sequence.
Rittal-style enclosure: more photos (9-fold build)
Factory photos of units from the same series. Multiple photos per product are allowed, shown exactly as shot on the shop floor.







This section shows factory photos. The image slot number is the shot list sequence number.
Where these cabinets go
These are the routine applications — we can talk scheme and configuration directly. For the industry view, see the industry pages.
Equipment control
Houses PLCs and VFDs for equipment automation control.
Power distribution
Houses breakers and busbars for power distribution.
Data centers and equipment rooms
Houses network equipment and servers in a 19-inch rack.
Large assembled systems
Multiple cabinets bayed together to form large assembled systems.
Machine tools and production lines
Electrical control cabinet packages for machine tools and production lines.
Export projects
European and US standard cabinet structure with interchangeable accessories, making overseas maintenance easier.
Commercial terms
Specification dated September 2026; quotations follow this.
| Drawings & design | Free |
| MOQ | 1 unit (5 or more recommended for production) |
| Production lead time | 15-25 days after drawing approval |
| on-time delivery | 98% |
| Warranty | 12 months |
| Loading port | Ningbo / Shanghai, China |
| Component brands | Schneider / ABB / Siemens / Chint |
| Factory visit & dispatch confirmation | Factory visits welcome; finished-cabinet photos and video before dispatch |
| Capacity | 5,800+ units / year |
Documents for your engineering team
Selection manual, outline dimensions and RFQ checklist — for the customer's electrical engineer. All three documents are being organized by product line; download links go live once complete.
Six questions procurement and electrical engineers ask most
What is the difference between a Rittal-style cabinet and an original-brand cabinet?
The structural system comes from the same origin: both use a 9-fold profile frame, 25 mm module and standard interchangeable accessories. The difference is brand and country of origin. What we build is a profile cabinet to the same standard, with accessories interchangeable with standard cabinets and a cost advantage.
Can the cabinets be bayed?
Yes. The frame has pre-drilled bayed-cabinet holes, so multiple cabinets can be bayed side by side for flexible expansion. The number of bayed cabinets depends on your system requirements — we provide the baying plan.
Are the accessories interchangeable with standard cabinets?
Yes. DIN rails, wire ducts and mounting plates are made to the 25 mm module and are interchangeable with European and US standard cabinet accessories. Later maintenance and add-ons won't send you hunting for non-standard parts.
Can dimensions and color be customized?
Yes. Dimensions, door type, cutouts, internal structure, and powder-coat color are all built to drawing. Colors are specified per the RAL color card, and color stays consistent across production runs on engineering projects.
Can it hold 19-inch equipment?
Yes. We fit a 19-inch mounting frame for network equipment and servers. We build this type of cabinet too, sharing the same frame system as our control cabinets and distribution cabinets.
What do you need for a quote?
Application, cabinet type (wall-mounted / floor-standing / multi-cabinet lineup), dimensions or bill of materials, ingress protection (IP) rating, door type and color requirements, and whether you need a viewing window or 19-inch frame. Drawings are best if you have them.
Other cabinet types in the same main circuit
Related products use color-block placeholders for now (product photos not yet complete; they will be replaced together). Internal links will be filled in once live URLs are confirmed.
Need a standardized cabinet structure? We build profile-frame cabinets to drawing
Send us your application, dimensions, and structural requirements for a free Rittal-style cabinet proposal · quote within 24 hours. Direct from the source factory, MOQ 1 unit, 15–25 day delivery, 1-year warranty.
ISO 9001:2015 · CE(LVD+EMC) · CQC · IP65
When you write, include: single-line diagram or primary scheme, switch room layout, load list, and component brand requirements. You do not need complete drawings — capacity and cabinet type are enough to start.