IK10 impact-resistant enclosures
- Rating: designed to IEC 62262 / GB/T 20138 IK10 (20 J impact); reports provided per project
- Structure: 2.0 mm door with internal stiffening ribs, 2.5 mm frame, internal hinge pins
- Lock: three-point interlocking lock recessed inside the door, drill- and pry-resistant lock cylinder
- Applications: EV charging stations, transit shelter equipment, venue controls, exposed enclosures in open plant areas
- Protection: IK10 impact resistance and IP54/IP65 ingress protection met simultaneously (per project specification)
Specifications
The table below covers 80% of factory distribution room cases. Anything outside it we can still build — those are engineered items, quoted separately, with an indicative price the same day.
| Impact Rating | Designed to IEC 62262 / GB/T 20138 IK10 (20 J); test reports provided per project requirements |
|---|---|
| Standard sizes (W×D×H) | 600×500×1500 / 800×600×1800 mm and others; custom build available |
| Sheet thickness | 2.0 mm door with internal stiffening ribs / 2.5 mm frame posts |
| Hinge | Internal hinge pins (no removable pin on the outside) |
| Lock | Three-point interlocking lock recessed inside the door, drill- and pry-resistant lock cylinder |
| Surface treatment | Outdoor hot-dip galvanized + dual coating / bare stainless steel (by application) |
| IP rating | IP54 / IP65 and IK10 met simultaneously (per project specification) |
| Mounting | Anchor bolts + base grouting (anti-tamper for public areas) |
| Door construction | Vertical door stiffeners + vibration-damping pads; door still opens normally after impact deformation |
|---|---|
| Locking points | Three-point concealed compression (top, center, bottom); no leverage point for a pry bar |
| Viewing window | PC window (impact-resistant) instead of glass, supplied as required |
| Tamper-resistant fasteners | All external screws are hex socket / tamper-resistant |
| Ventilation | Concealed bottom ventilation + anti-blocking mesh (prevents foreign object insertion) |
| Grounding | Main grounding point M8, door bonded with braided strap |
| EV charging station cabinet | Power and control cabinet for street / parking lot EV charging stations |
|---|---|
| Transit platform equipment cabinet | Control and information equipment cabinet for bus / transit shelters |
| Venue control cabinet | Lighting / audio control cabinet for stadiums and open venues |
| Exposed plant cabinet | Pump control and lighting cabinet for open plant areas without perimeter fencing |
| Landscape support cabinet | Water supply, drainage and lighting control cabinet for parks / plazas |
| Custom build | Customized to equipment form factor and mounting position; impact rating specification not reduced |
| Impact standard | IEC 62262 / GB/T 20138 (IK code, IK10 = 20 J) |
|---|---|
| Structural verification | After 20 J impact: ingress protection intact, door opens normally, live parts not accessible |
| Structural standard | GB/T 7251.1 / IEC 61439-1 (mechanical structure section) |
| Fastener inspection | External tamper-resistant fastener specification checked unit by unit |
| Documents with shipment | Outline drawing, reinforcement structure drawing, impact verification records (per project specification) |
Five steps to specify your run
A configuration summary is generated as you go. It travels with your inquiry, saving a round of confirmation.
Build details
Systems have been in service for decades, and the failure points are always the same few: poor busbar contact, water ingress at the door seal, high temperature rise in the correction cabinet, and mis-phased outgoing feeders. The six hard rules below are written for exactly these points — every cabinet can be traced to them.
IK10 comes from structure, not plate thickness
2.0 mm door panel + vertical reinforcing rib liner — impact energy disperses along the ribs. Simply stacking plate thickness to 3 mm is dead weight; the rib structure is the real answer to 20 J.
Still serviceable after a hit
IK10 acceptance is not just about surviving the strike: after a 20 J impact, the door must still open normally and the lock must still function. A cabinet that cannot be opened after one impact is a dead cabinet no matter how high its protection rating.
No removable pin on the outside
The hinge pin is internal — nothing removable can be reached from outside the cabinet. An exposed pin can be knocked out with one strike, and the door comes off.
The keyhole is not the weak point
The lock cylinder bore is lined with a hardened anti-drill shield, and the cylinder sits deep. Three-point compression leaves a pry bar no fulcrum. The lock position is always the first point of attack on a cabinet — that is where material matters most.
Nothing can be pushed in
Concealed bottom ventilation + anti-tamper mesh. In public locations, objects pushed into a cabinet cause more damage (short circuit and fire) than a forced door.
Reports provided per project
IK10 is delivered to the design specification; third-party test reports are provided per project requirements. Test lead time and cost are stated clearly at the project stage — no surprises after the fact.
Photos & enclosure construction
Below are photos taken in our own shop — from the complete unit down to the internal busbars and secondary wiring. Every build detail can be checked item by item.



Image key: 01–05 are shop photos (the numbers match the shot list). The line drawing shows the front elevation of the enclosure; dimensions match the specification table above.
Where these cabinets go
These are the routine applications — we can talk scheme and configuration directly. For the industry view, see the industry pages.
EV charging station cabinet
Power and control cabinets for street and parking lot charging equipment, built to take impact and resist prying.
Transit platforms and shelters
Information and control equipment for bus platforms, in high-foot-traffic locations.
Venues and plazas
Open-site installation of lighting and audio control cabinets.
Open industrial sites
Pump control and lighting cabinets in areas without perimeter fencing, unattended at night.
Park water supply and drainage
Landscape-area water supply and drainage control cabinet, finished to match the surrounding architectural coating.
Retrofit & reinforcement
Existing public-area enclosures re-skinned to an IK10 structure, reusing the existing foundation.
Commercial terms
Specification dated September 2026; quotations follow this.
| Drawings & design | Free |
| MOQ | 1 unit (5 or more recommended for production) |
| Production lead time | 15-25 days after drawing approval |
| on-time delivery | 98% |
| Warranty | 12 months |
| Loading port | Ningbo / Shanghai, China |
| Sheet steel | Baosteel / Ansteel cold-rolled sheet (SPCC) / 304 stainless steel |
| Factory visit & dispatch confirmation | Factory visits welcome; finished-cabinet photos and video before dispatch |
| Capacity | 5,800+ units / year |
Documents for your engineering team
Selection manual, outline dimensions and RFQ checklist — for the customer's electrical engineer. All three documents are being organized by product line; download links go live once complete.
Six questions procurement and electrical engineers ask most
What does IK10 actually mean?
The highest class of external mechanical impact protection under IEC 62262 / GB/T 20138: a 5 kg striker dropped from 0.4 m delivers 20 J of impact energy to the enclosure surface, and protection and safety performance must not fail. In plain terms: hit it with a hammer and the cabinet keeps working.
Can a cabinet be IK10 and IP65 at the same time?
Yes. IK covers impact resistance and IP covers dust and water ingress — two independent ratings. Public outdoor installations usually need both, with the structure and test plan set by the project specification.
Do you have an IK10 certificate?
We design and deliver to the IK10 rating, and third-party test reports are provided to project requirements — testing requires sample submission and involves lead time and cost. If your project needs it, say so at the quotation stage and we will arrange it accordingly.
Is the price much higher than a standard enclosure?
The structural differences are door stiffening ribs, a recessed lock, internal pin hinges and tamper-resistant fasteners, which puts a same-size unit one cost tier above a standard enclosure. There is no need for IK10 in a closed electrical room with no public access — spend the money where it counts.
Can the viewing window be glass?
Viewing windows on an IK10 cabinet use PC (polycarbonate), not glass — glass cannot reach the required impact rating on its own and would be the weak point in an otherwise IK10 enclosure.
If it gets dented, can it be repaired?
The door stiffening ribs absorb most of the impact, and standard parts (door, lock, hinges) can be replaced individually — that is the value of the "door opens after impact" design: replace the damaged part, leave the enclosure alone.
Other cabinet types in the same main circuit
Related products use color-block placeholders for now (product photos not yet complete; they will be replaced together). Internal links will be filled in once live URLs are confirmed.
For enclosures in public areas, send us installation photos and we will define the solution
Send installation site photos and your equipment list, and we will provide a free IK10 structural proposal and quotation · reply within 24 hours · testing reports arranged per project. Direct from the source factory, MOQ 1 unit, 1-year warranty.
ISO 9001:2015 · CE(LVD+EMC) · CQC · IP65
When you write, include: single-line diagram or primary scheme, switch room layout, load list, and component brand requirements. You do not need complete drawings — capacity and cabinet type are enough to start.