Home/Products/Low-Voltage Distribution & Assemblies/GCS/GCK drawer-type switchgear
B U I L D T O D R A W I N G GCK draw-out switchgear, front view (multiple draw-out units per cabinet, panel indicators)
PRODUCT — 02 · Low-Voltage Distribution & Assemblies

GCS/GCK drawer-type switchgear

Pull it out to service, push it back to run
Model GU-GCS · 380/400V · horizontal busbar GCS ≤4000A / GCK ≤2500A · MOQ 1 unit
GCS/GCK drawer cabinets turn feeders and motor control into standard drawer units: a faulty circuit is withdrawn for maintenance while the other circuits in the same cabinet stay energized. Unit sizes are graded 8E/16E/24E/48E, with up to a dozen-plus circuits per cabinet. GCS horizontal busbar up to 4000 A, GCK up to 2500 A. The division of work with GGD: GGD fixed cabinets for main incoming, metering and compensation; drawer cabinets for multi-circuit feeders and frequently operated motor control. Mixing both in one section is the classic switchroom layout.
  • Drawer units: 8E/16E/24E/48E sizes, multiple circuits per cabinet (feeders + motor control mixed)
  • Busbar: GCS horizontal busbar ≤4000 A / GCK ≤2500 A, 380/400V
  • Five-prevention interlock: drawer position (connected / test / disconnected) interlocked with the breaker to prevent misoperation
  • Maintenance: faulty unit withdrawn for repair or swapped as a whole, other circuits in the same cabinet stay energized
  • Components: molded case circuit breaker + contactor + thermal relay (motor units), brand selectable
≤4000 AGCS horizontal busbar
8E–48EDrawer unit sizes
No outageService one circuit while the rest run
1 unitMOQ 1 unit · ≥5 recommended for volume production
01 — SPECIFICATION

Specifications

The table below covers 80% of factory distribution room cases. Anything outside it we can still build — those are engineered items, quoted separately, with an indicative price the same day.

TypeGCS / GCK low-voltage withdrawable switchgear, floor-mounted against the wall or free-standing
Standard sizes (W×D×H)800(1000)×600(800)×2200 mm, custom build available
Enclosure constructionProfile frame + metal partitions into compartments (busbar compartment / unit compartment / cable compartment)
Drawer unit8E / 16E / 24E / 48E sizes, mixed in one cabinet
Position and InterlockingFour positions — connected / test / disconnected / withdrawn — with interlocking to prevent live plug-in or removal
IP ratingIP30 (electrical room) / IP42 optional
Rated voltageAC 380V / 400V, 50 Hz
Horizontal busbarGCS ≤4000 A / GCK ≤2500 A
Vertical busbar≤1000 A (verified against total unit capacity)
Short-time withstand current, Icw50 kA / 80 kA (matched to the main breaker interrupting capacity)
Feeder unitMolded-case circuit breaker units, covering unit ratings below 630 A
Motor unitBreaker + contactor + thermal overload relay / multifunction protection relay, drawout MCC unit
Secondary interfaceDrawout primary plug + secondary plug (32-pin standard); secondary circuit stays connected while the unit is withdrawn
Component brandsSchneider / ABB / Siemens / Chint; customer-supplied components accepted for factory installation
Feeder-intensive configuration8–14 feeder circuits per cabinet, replacing multiple GGD feeder cabinets
Motor control configuration (MCC)Drawout motor units grouped together; fan and pump groups can be operated without taking the cabinet offline
GGD + drawout hybrid configurationMain incoming / power factor correction GGD + drawout feeder cabinets — a classic electrical room section
Retrofit and expansion typeReplacing old cabinets with drawout cabinets, with busbar T-connections or full-section replacement
Dual-source drawout configurationIncoming ATS + drawout feeders in a single section
Assembly standardGB/T 7251.1 / IEC 61439-1; drawout construction verified to type-test criteria
Interlock verificationEach cabinet is verified for four-position interlocking and live plug-in/removal blocking
Plug inspectionPrimary / secondary plugs checked unit by unit (contact resistance re-measured after 5 withdraw/insert cycles)
Routine tests (every unit)Insulation resistance, dielectric withstand, and energized tests on busbars and units
Documents with shipmentSystem diagram, unit cross-reference table, plug wiring table, BOM, test report
02 — CONFIGURATOR

Five steps to specify your run

A configuration summary is generated as you go. It travels with your inquiry, saving a round of confirmation.

01Type
02Unit composition
03Busbar current
04Component brands
05Options (multiple)
03 — CRAFT

Build details

Systems have been in service for decades, and the failure points are always the same few: poor busbar contact, water ingress at the door seal, high temperature rise in the correction cabinet, and mis-phased outgoing feeders. The six hard rules below are written for exactly these points — every cabinet can be traced to them.

Compartment isolation

A fault can't burn through to the next unit

Metal partitions separate the busbar compartment, unit compartment and cable compartment, with flame-retardant barriers between units: an arc fault in one unit is confined to its own compartment — this is the core structural reason a drawer cabinet is safer than a fixed cabinet.

Durable plug-in contacts

Retested after five insertions

Primary and secondary plug-in contacts are inserted and withdrawn 5 times per unit, then contact resistance is retested — plug-in contacts are the number one failure point in drawer cabinets, and this is caught at the factory.

Interlocks in place

Can't insert under power

The drawer will not close in any position other than connected, and can only be removed in the disconnected position; the handle interlock works together with the position switch and is verified unit by unit: a physical barrier against misoperation is more reliable than training.

Busbar pass-through

Factory-prefabricated busbar sections

Horizontal busbars between cabinets are factory-prefabricated and continuous, torque-tightened and marked with witness lines, then bolted together on site; when mixed with GGD, the transition keeps the same cross-section — no downgrade.

Unit-to-schedule match

Drawer number equals circuit number

Each drawer is labeled by circuit number, and the unit cross-reference table ships with the order: a spare drawer can be swapped in without tracing wires, and the cabinet faceplate matches the drawings.

Secondary circuit stays live

Test position allows commissioning

Push the drawer to the test position: the main circuit is open while the secondary circuit remains live, so the unit can be commissioned under no load inside the cabinet without affecting running circuits.

04 — EVIDENCE

Photos & enclosure construction

Below are photos taken in our own shop — from the complete unit down to the internal busbars and secondary wiring. Every build detail can be checked item by item.

GCK draw-out switchgear, front view (multiple draw-out units per cabinet, panel indicators)
GCK draw-out switchgear, front view (multiple draw-out units per cabinet, panel indicators)
GCK vertical busbar compartment (yellow, green and red phase busbars, current transformers and secondary terminals)
GCK vertical busbar compartment (yellow, green and red phase busbars, current transformers and secondary terminals)
GCK draw-out unit, close-up (draw-out unit, branch busbars and secondary components inside the cabinet)
GCK draw-out unit, close-up (draw-out unit, branch busbars and secondary components inside the cabinet)
FRONT VIEW Power meter Status indication Channel base at the bottom · inter-cabinet busbars run through H 2200 W 800 / 1000 / 1200 IP54 standard IP65 optional Ue 400V ≤2000A Icw 30–65kA
Verifiable build checklist:2.0 mm seam-welded enclosure · diagonal ≤1.5 mm · busbar torqued to 30-40 N·m with witness marks · busbar joint temperature rise ≤70 K · segregated wiring compartments · CTs and meters in separate compartments · 60-80 μm coating · 2500 V/1 min withstand on every unit.

Image key: 01–05 are shop photos (the numbers match the shot list). The line drawing shows the front elevation of the enclosure; dimensions match the specification table above.

05 — APPLICATIONS

Where these cabinets go

These are the routine applications — we can talk scheme and configuration directly. For the industry view, see the industry pages.

Plant distribution room feeders

Multiple circuits centralized, replacing several fixed cabinets.

MCC motor control

Centralized operation of pump groups and fan groups, with unit-level maintenance.

Commercial building distribution

Floor and power feeders in drawer form, maintenance-friendly for property management.

Retrofit & Capacity Expansion

Replace fixed sections with drawer sections to double the circuit count.

Data Centers / Server Rooms

A typical case with many feeder circuits and frequent operation.

Mixed with GGD

Fixed incoming and compensation sections plus drawer feeders — all in one lineup.

06 — TERMS

Commercial terms

Specification dated September 2026; quotations follow this.

Drawings & designFree
MOQ1 unit (5 or more recommended for production)
Production lead time15-25 days after drawing approval
on-time delivery98%
Warranty12 months
Loading portNingbo / Shanghai, China
Component brandsSchneider / ABB / Siemens / Chint
Factory visit & dispatch confirmationFactory visits welcome; finished-cabinet photos and video before dispatch
Capacity5,800+ units / year
07 — DOWNLOADS

Documents for your engineering team

Selection manual, outline dimensions and RFQ checklist — for the customer's electrical engineer. All three documents are being organized by product line; download links go live once complete.

PDFSelection and configuration manualTechnical highlights, specifications, typical solutions and commercial termsIn progress · pending
DXFCommon outline & cut-out dimensionsFront view / side view / foundation and cable entry cutoutsIn progress · pending
XLSRFQ data checklistInformation to confirm before quoting — fill in and send backIn progress · pending
08 — FAQ

Six questions procurement and electrical engineers ask most

GCS or GCK — which one?

GCS: horizontal busbar up to 4000 A and higher circuit density, for high-current, many-circuit applications. GCK: 2500 A class, simpler construction, good value for standard feeders. In the same lineup, GCS is common for the high-current main incoming section and GCK for smaller feeder sections — we confirm after working through the circuit schedule.

How do drawer cabinets and GGD fixed cabinets split the work?

GGD is simple and inexpensive: use it for circuits that are set and left alone — main incoming, metering, compensation. Drawer cabinets cost more but allow unit-level service: use them for circuits that are operated often — feeders and motor control. The classic switchroom layout mixes both.

How much current can one drawer carry?

By unit size: an 8E unit handles about 63 A, 16E up to the 250 A class, 24E/48E up to 630 A. Higher-current circuits (air circuit breaker incoming) are usually fixed or large-unit designs. We lay out the unit scheme from your circuit schedule.

Can a drawer really be serviced without stopping other circuits?

Pull a faulty unit for repair or swap in a spare drawer and the other circuits in the same cabinet keep running — provided the cabinet has compartment isolation and the plug-in contacts are properly specified. That is the core value of a drawer cabinet: the service window shrinks from shutting down a whole section to shutting down one circuit.

Do plug-in secondary circuits tend to make poor contact?

It is a common issue with drawer cabinets, so our factory process adds a 5-cycle plug-in retest. For routine annual maintenance, exercise every drawer through a full plug-in cycle and reseat it — the contact surfaces self-clean. One spare set of secondary plug-in terminals is enough.

Can it be upgraded to a smart cabinet?

Yes: add smart meters or motor protection relays to the units, network them over RS485 to report circuit current, energy and status, and capture drawer position signals as well. We do this for both existing-cabinet retrofits and new-build options, with the point list issued as needed.

09 — RELATED

Other cabinet types in the same main circuit

Related products use color-block placeholders for now (product photos not yet complete; they will be replaced together). Internal links will be filled in once live URLs are confirmed.

10 — RFQ

Send the circuit schedule and we lay out the unit scheme from it

Send your circuit schedule (application / rating / motor data) and we will provide a drawer unit layout at no charge · quotation within 24 hours. Direct from the source factory, MOQ 1 unit, 15–25 day delivery, 1-year warranty.

Email your inquiry WhatsApp: +86 186 5712 0011
GU ELECTRIC (Zhejiang Golden Unicorn) · 5,000 sqm workshop, Fengchuan Industrial Zone, Tonglu · 20 people · 5,800+ units per year
ISO 9001:2015 · CE(LVD+EMC) · CQC · IP65

When you write, include: single-line diagram or primary scheme, switch room layout, load list, and component brand requirements. You do not need complete drawings — capacity and cabinet type are enough to start.

GCS/GCK Drawer Cabinets · MOQ 1 Unit · 15–25 Days Get a quote