GU ELECTRIC — Beyond the CabinetGU ELECTRIC — Beyond the Cabinet Get a quote
B U I L D T O D R A W I N G End distribution box, full front view (wall-mounted enclosure with door closed; viewing window and door lock visible on the front)
PRODUCT — 02 · Low-Voltage Distribution & Assemblies

Final distribution boards

The gatekeeper of the last meter of power
Model GU-FDB · modular ≤63 A · 1P+N / residual current module · MOQ 1 unit
The terminal distribution box is the last stop in the circuit: after the main switch, the incoming supply is split by function into end circuits for lighting, sockets, air conditioning, kitchen and bathroom, each protected by a 1P+N modular circuit breaker, with a residual current module (30 mA) on circuits in wet locations. The enclosure is flush-mounted (rough-in frame) or surface-mounted, with comb busbar clamping and separate neutral and ground bars; circuit labels ship with the goods so handover inspection and maintenance are clear at a glance.
  • Circuits: separate lighting / socket / air conditioning / kitchen and bathroom circuits, 1P+N modular MCBs
  • Residual current: 30 mA residual current modules on wet-location and socket circuits — the baseline for personnel safety
  • Main switch: isolator or 2P MCB ≤63 A with isolation indication
  • Enclosure: flush mount (rough-in frame + trim frame) / surface mount, usable depth according to circuit count
  • Labels: circuit labels and system drawing ship with the goods — no guesswork at handover inspection
≤63 AIncoming current
1P+NPhase and neutral switched together
30 mAResidual current on wet-location circuits
1 unitMOQ 1 unit · ≥5 recommended for volume production
01 — SPECIFICATION

Specifications

The table below covers 80% of factory distribution room cases. Anything outside it we can still build — those are engineered items, quoted separately, with an indicative price the same day.

Enclosure typeFlush mount (rough-in frame + trim frame) / surface mount
Standard dimensions (W×H×D)8–45 ways depending on circuit count: 260×360×90 to 500×700×120 mm
Enclosure construction1.0–1.2 mm cold-rolled steel rough-in frame + trim frame, electrostatic powder coated
IP ratingIP30 (indoor recessed / surface mount)
Door and trimFlush transparent door or no door, trim frame flush with the finished wall
Cable entryKnockouts on top and bottom, flush-mount rough-in to drawing
Rated voltageAC 220/380V, 50 Hz
main breaker2P / 3P isolator or MCB ≤63 A
outgoing feeders1P+N MCBs, 6–45 ways; C / D curve selected by load
RCD moduleSocket / kitchen / bath circuits at 30 mA; main RCD 100/300 mA optional
Surge protectionReserved SPD slots, Type 1 / Type 2 (buildings and standalone structures)
Neutral and ground barsSeparate N bar and PE bar, sized by circuit
Component brandsChint / Schneider / ABB / Siemens, customer-supplied and shipped to factory accepted
Residential unit typeLighting / socket / AC / kitchen / bath / bathroom heater circuits, 30 mA RCD on each
Apartment rental typeSub-metering upstream (with meter box) + in-unit final circuits
Commercial storefront typeMultiple lighting circuits + sockets + dedicated AC line + storefront sign circuit
Office typeWorkstation socket circuits and lighting on separate circuits; UPS slot reserved
Retrofit cabinet replacement typeOld box replacement: 1:1 on existing circuits, labels kept to site convention
Assembly standardGB/T 7251.1 and GB/T 7251.3 (particular requirements for distribution boards)
Routine tests (every unit)Insulation resistance, dielectric withstand, circuit-by-circuit continuity and RCD trip test
Temperature riseTerminal connections ≤70 K
Label verificationCircuit labels checked against the system diagram, unit by unit
Documents with shipmentSystem diagram, circuit labels, BOM, test report
02 — CONFIGURATOR

Five steps to specify your run

A configuration summary is generated as you go. It travels with your inquiry, saving a round of confirmation.

01Number of ways
02main breaker
03Enclosure type
04Component brands
05Options (multiple)
03 — CRAFT

Build details

Systems have been in service for decades, and the failure points are always the same few: poor busbar contact, water ingress at the door seal, high temperature rise in the correction cabinet, and mis-phased outgoing feeders. The six hard rules below are written for exactly these points — every cabinet can be traced to them.

Every circuit in place

Circuits by use

Lighting, sockets, AC, and kitchen/bath each run on their own circuit: a fault affects the smallest possible area, and when a breaker trips you know where to look. Circuits are divided by use, not by room count — that is the basics of a terminal box.

1P+N

Phase and neutral break together

Outgoing circuits use 1P+N double-break MCBs: phase and neutral open together during service, so even the wrong wire is dead — costs only a few yuan more per pole than single-break 1P, but a different order of safety.

Leakage protection throughout

30 mA on damp circuits

Receptacle, kitchen and bathroom circuits all get 30 mA leakage protection — personal safety is not a cost-benefit question. The main leakage device handles fire protection (300 mA); the two levels work independently.

Comb busbar

No flying leads

Distribution is crimped onto a comb busbar — no wire knots inside the box. Adding a circuit later means pulling one slot and plugging in; existing wiring stays untouched.

Labels ship with the box

No guesswork at handover

Circuit labels plus a laminated system diagram inside the door ship with the box. At handover, read the diagram and call out the names — anyone can see which breaker controls which circuit.

Adequate clear depth

No rework on flush mounts

Flush-mount boxes are sized with enough clear depth for wire gauge and bend radius, and the rough-in frame is leveled during installation — ten extra minutes at the civil works stage means no wall demolition later.

04 — EVIDENCE

Photos & enclosure construction

Below are photos taken in our own shop — from the complete unit down to the internal busbars and secondary wiring. Every build detail can be checked item by item.

End distribution box, full front view (wall-mounted enclosure with door closed; viewing window and door lock visible on the front)
End distribution box, full front view (wall-mounted enclosure with door closed; viewing window and door lock visible on the front)
304 stainless steel meter box · Photo 01
304 stainless steel meter box · Photo 01
304 stainless steel meter box · Photo 02
304 stainless steel meter box · Photo 02
FRONT VIEW Power meter Status indication Channel base at the bottom · inter-cabinet busbars run through H 2200 W 800 / 1000 / 1200 IP54 standard IP65 optional Ue 400V ≤2000A Icw 30–65kA
Verifiable build checklist:2.0 mm seam-welded enclosure · diagonal ≤1.5 mm · busbar torqued to 30-40 N·m with witness marks · busbar joint temperature rise ≤70 K · segregated wiring compartments · CTs and meters in separate compartments · 60-80 μm coating · 2500 V/1 min withstand on every unit.

Image key: 01–05 are shop photos (the numbers match the shot list). The line drawing shows the front elevation of the enclosure; dimensions match the specification table above.

05 — APPLICATIONS

Where these cabinets go

These are the routine applications — we can talk scheme and configuration directly. For the industry view, see the industry pages.

New residential builds and whole-home renovations

Circuit plans by unit layout, done right the first time.

Apartments and rental units

Per-unit terminals plus metering provisions for clear management.

Commercial storefronts and food service

Separate lighting, receptacle and AC circuits; dedicated kitchen lines.

Office workstations

Zoned receptacle and lighting circuits per workstation, with UPS provisions.

Standalone buildings and villas

Multiple boxes across floors plus SPD surge protection.

Old panel replacement

1:1 replacement against existing circuits, keeping familiar labels.

06 — TERMS

Commercial terms

Specification dated September 2026; quotations follow this.

Drawings & designFree
MOQ1 unit (5 or more recommended for production)
Production lead time15-25 days after drawing approval
on-time delivery98%
Warranty12 months
Loading portNingbo / Shanghai, China
Component brandsSchneider / ABB / Siemens / Chint
Factory visit & dispatch confirmationFactory visits welcome; finished-cabinet photos and video before dispatch
Capacity5,800+ units / year
07 — DOWNLOADS

Documents for your engineering team

Selection manual, outline dimensions and RFQ checklist — for the customer's electrical engineer. All three documents are being organized by product line; download links go live once complete.

PDFSelection and configuration manualTechnical highlights, specifications, typical solutions and commercial termsIn progress · pending
DXFCommon outline & cut-out dimensionsFront view / side view / foundation and cable entry cutoutsIn progress · pending
XLSRFQ data checklistInformation to confirm before quoting — fill in and send backIn progress · pending
08 — FAQ

Six questions procurement and electrical engineers ask most

How many circuits do I need?

By function, not by room: 2–3 lighting circuits, 2–3 general receptacle circuits, 1 circuit per AC unit, 1–2 kitchen circuits, 1 bathroom circuit, plus 20% spare. A three-bedroom home typically runs 18–24 ways. Send us your floor plan and we will produce a circuit schedule free of charge.

1P or 1P+N?

1P breaks only the phase; 1P+N breaks phase and neutral together. During service, the neutral can carry voltage from another circuit — 1P+N isolates cleanly. The price difference is a few yuan per pole. We default to 1P+N rather than save small change and leave a hazard.

Leakage protection on the main or on branch circuits?

Personal protection comes from 30 mA branch devices (receptacles / kitchen / bathroom); fire protection comes from a 100/300 mA main device — the two levels work together. A main device alone saves money, but one leaking circuit blacks out the whole home. On a tight budget, at minimum put branch leakage protection on damp locations.

When does the flush-mount box arrive on site?

The rough-in frame arrives before plastering (cutout dimension drawings ship with it); the trim frame and door go in during finish work — a two-stage delivery. Finalize the system diagram before electrical rough-in to avoid changing circuits on site.

Can SPD be included?

Yes: standalone buildings and end-of-line supply points should have a Type 2 SPD module (plug-in, replaceable when degraded); buildings with upstream distribution room protection can simplify. In high-lightning areas, specify SPD as standard.

What should I watch for when replacing an old panel?

Three things to check: circuit-by-circuit 1:1 correspondence (keep the original numbering), incoming supply spec verification (does the old wire gauge match the new breaker), and grounding confirmation (for older homes with no ground wire, resolve the grounding first or use residual current protection as an alternative). Send photos for a free assessment.

09 — RELATED

Other cabinet types in the same main circuit

Related products use color-block placeholders for now (product photos not yet complete; they will be replaced together). Internal links will be filled in once live URLs are confirmed.

10 — RFQ

Send your floor plan — circuit schedule at no charge

Send your floor plan or circuit requirements and we will provide a circuit division and enclosure plan at no charge · Quotation within 24 hours. Direct from the source factory, MOQ 1 unit, 15–25 day lead time, 1-year warranty.

Email your inquiry WhatsApp: +86 186 5712 0011
GU ELECTRIC (Zhejiang Golden Unicorn) · 5,000 sqm workshop, Fengchuan Industrial Zone, Tonglu · 20 people · 5,800+ units per year
ISO 9001:2015 · CE(LVD+EMC) · CQC · IP65

When you write, include: single-line diagram or primary scheme, switch room layout, load list, and component brand requirements. You do not need complete drawings — capacity and cabinet type are enough to start.

Terminal distribution box · MOQ 1 unit · 15–25 days Get a quote