Explosion-proof control cabinets

In hazardous areas, control must also be fail-safe
Model GU-EXP · Ex d / Ex e / Ex p · Hazardous area control · PLC/VFD integration available · Customized per scheme
On top of an explosion-proof distribution box, an explosion-proof control cabinet adds control functions — equipment start/stop, interlocking, and even PLC logic and variable frequency speed control in hazardous areas, all completed inside an explosion-proof enclosure. The challenge is fitting control functions into an explosion-proof structure: operating elements must be explosion-proof types, cable entries must be explosion-proof sealed, and heat-generating components such as PLC and VFD also require a balance between heat dissipation and explosion protection. We produce and supply in joint supply with a professional factory holding Ex qualifications, getting both the control functions and the explosion-proof requirements right together.
  • Protection type: Ex d flameproof / Ex e increased safety / Ex p pressurized, selected by hazardous zone and gas group
  • Control functions: equipment start/stop, interlocking, PLC logic, variable frequency speed control can be integrated
  • Explosion-proof operation: explosion-proof operating handles, indicator lights and pushbuttons configured to explosion-proof requirements
  • Qualification: produced in joint supply with an Ex-qualified manufacturer; Ex certificates available for verification
  • Heat dissipation balance: heat dissipation and explosion protection balance design for heat-generating PLC/VFD components
Ex d/e/pType of protection
Can integratePLC / VFD control
Zone 1/2Gas hazardous zone
VerifiableExplosion-Proof Certificate
01 — SPECIFICATION

Specifications

The table below covers 80% of factory distribution room cases. Anything outside it we can still build — those are engineered items, quoted separately, with an indicative price the same day.

Type of protectionEx d flameproof / Ex e increased safety / Ex p pressurized, selected by hazardous zone and gas group
Hazardous areaZone 1 / Zone 2 gas, Zone 21 / 22 dust (configured by classification)
MaterialCast aluminum / steel plate / stainless steel, selected by protection type and environment
Standard dimensionsCustomized by number of circuits, control functions and protection type
Surface treatmentExplosion-proof surface treatment; weather-resistant and anti-corrosion for outdoor models
IP ratingIP65 / IP66 (in combination with the protection type)
Operating elementsExplosion-proof operating handles, indicator lights and pushbuttons configured to explosion-proof requirements
QualificationsManufactured and supplied in joint supply with an Ex-qualified manufacturer; Ex certificate available for verification
Control functionEquipment start/stop, interlocking, PLC logic, variable frequency speed control can be integrated
PLC integrationPLC control in an explosion-proof environment, laid out to explosion-proof requirements
VFD integrationVariable frequency speed control in an explosion-proof environment, with heat dissipation and explosion protection balance design
Explosion-proof ratingEx d / Ex e / Ex p, gas group IIA / IIB / IIC, temperature class T1–T6
Circuit configurationControl circuits, components and cable entries customized to project and explosion-proof requirements
GroundingExplosion-proof grounding requirements, grounding continuity testing
Equipment start/stop controlLocal / remote start/stop control of equipment in hazardous areas
Interlock controlSafety interlocking control of equipment in hazardous areas
PLC controlPLC logic control for hazardous-area processes
VFD speed controlVariable frequency drive control of hazardous-area motors
Pressurized control cabinetEx p pressurized, high-capacity control in hazardous areas
Build to drawingControl scheme custom-built to project and explosion-proof requirements
Reference standardsGB/T 3836.1–.4 (explosive atmospheres) series / IEC 60079 series
Type of protectionEx d flameproof / Ex e increased safety / Ex p pressurized, per the relevant type standard
Gas groupIIA / IIB / IIC, temperature class T1–T6
IP ratingGB 4208 / IEC 60529, IP65 / IP66
Certification verificationEx certificate available for verification; certification documents shipped with the goods
Factory testsExplosion-proof construction inspection, control function, circuit check, dielectric withstand, grounding continuity
Documents with shipmentElectrical schematic, control logic description, explosion-proof certificate (for verification), BOM, test report, factory photos
02 — CONFIGURATOR

Five steps to specify your run

A configuration summary is generated as you go. It travels with your inquiry, saving a round of confirmation.

01Type of protection
02Control function
03Hazardous area
04Gas group
05Options (multiple)
03 — CRAFT

Build details

Systems have been in service for decades, and the failure points are always the same few: poor busbar contact, water ingress at the door seal, high temperature rise in the correction cabinet, and mis-phased outgoing feeders. The six hard rules below are written for exactly these points — every cabinet can be traced to them.

Control

Control functions inside explosion-proof construction

Start/stop, interlock, PLC and VFD functions go inside an explosion-proof enclosure, with explosion-proof operating elements. Control functions and explosion-proof requirements are engineered together — not a flameproof box with components stuffed in.

Cooling

Heat balance for heat-generating components

PLCs and VFDs generate significant heat, so heat dissipation and explosion-proof integrity must be balanced in the design. If heat-generating components are not handled properly, excessive temperature inside the explosion-proof enclosure is itself a hazard.

Qualifications

Joint supply with a specialized manufacturer

Explosion-proof products are manufactured and supplied in joint supply with a specialized manufacturer holding Ex qualifications. Ex certificates are available for verification, and qualification documents ship with the order.

Operation

Explosion-proof operating elements

Handles, pushbuttons and indicator lights are all explosion-proof types. For operation in hazardous areas, ordinary components are an ignition source.

Sealing

Cable entry via explosion-proof glands

Explosion-proof cable glands / sealing fittings are used for incoming and outgoing cables. With many control circuits, explosion-proof sealing at cable entries matters even more.

Custom build

Custom-built to explosion-proof requirements

Control scheme, circuits, components and cable entries are all custom-built to project and explosion-proof requirements.

04 — EVIDENCE

Photos & enclosure construction

Below are photos taken in our own shop — from the complete unit down to the internal busbars and secondary wiring. Every build detail can be checked item by item.

Explosion-proof control cabinet, front view (stainless steel enclosure, circular flameproof door with viewing window and instruments)
Explosion-proof control cabinet, front view (stainless steel enclosure, circular flameproof door with viewing window and instruments)
Explosion-proof control cabinet · Photo 01
Explosion-proof control cabinet · Photo 01
Stainless steel explosion-proof cabinet with circular flameproof door open (flameproof joint faces and internal components visible)
Stainless steel explosion-proof cabinet with circular flameproof door open (flameproof joint faces and internal components visible)
FRONT VIEW Power meter Status indication Channel base at the bottom · inter-cabinet busbars run through H 2200 W 800 / 1000 / 1200 IP54 standard IP65 optional Ue 400V ≤2000A Icw 30–65kA
Verifiable build checklist:2.0 mm seam-welded enclosure · diagonal ≤1.5 mm · busbar torqued to 30-40 N·m with witness marks · busbar joint temperature rise ≤70 K · segregated wiring compartments · CTs and meters in separate compartments · 60-80 μm coating · 2500 V/1 min withstand on every unit.

Image key: 01–05 are shop photos (the numbers match the shot list). The line drawing shows the front elevation of the enclosure; dimensions match the specification table above.

05 — APPLICATIONS

Where these cabinets go

These are the routine applications — we can talk scheme and configuration directly. For the industry view, see the industry pages.

Oil & Gas / Petrochemical

Control of equipment in hazardous areas of refining and storage facilities.

Pharma & Fine Chemicals

Process control in flammable solvent environments.

Gas & Energy

Equipment control for gas stations and LNG facilities.

Dust environment

Equipment control in dust hazardous areas.

Mining

Control in underground and surface hazardous areas.

Coatings & Spray Finishing

Equipment control in paint shops.

06 — TERMS

Commercial terms

Specification dated September 2026; quotations follow this.

Drawings & designFree
MOQ1 unit (5 or more recommended for production)
Production lead time15-25 days after drawing approval
on-time delivery98%
Warranty12 months
Loading portNingbo / Shanghai, China
Component brandsSchneider / ABB / Siemens / Chint
Factory visit & dispatch confirmationFactory visits welcome; finished-cabinet photos and video before dispatch
Capacity5,800+ units / year
07 — DOWNLOADS

Documents for your engineering team

Selection manual, outline dimensions and RFQ checklist — for the customer's electrical engineer. All three documents are being organized by product line; download links go live once complete.

PDFSelection and configuration manualTechnical highlights, specifications, typical solutions and commercial termsIn progress · pending
DXFCommon outline & cut-out dimensionsFront view / side view / foundation and cable entry cutoutsIn progress · pending
XLSRFQ data checklistInformation to confirm before quoting — fill in and send backIn progress · pending
08 — FAQ

Six questions procurement and electrical engineers ask most

What is the difference between an explosion-proof control cabinet and an explosion-proof distribution box?

An explosion-proof distribution box is mainly for power distribution. An explosion-proof control cabinet adds control functions on top of distribution — start/stop, interlock, PLC and variable frequency drive control. The control cabinet must also address explosion-proof operating elements and heat balance for heat-generating components, so the technical requirements are higher.

Can PLC and VFD be integrated?

Yes. PLC logic and variable frequency speed control can be integrated in explosion-proof environments, but the heat dissipation versus explosion-proof balance has to be solved. Heat-generating components need dedicated design, and we handle that as part of the solution.

Do you hold explosion-proof certification yourselves?

Our explosion-proof products are manufactured and supplied in joint supply with an Ex-qualified manufacturer. We can provide the explosion-proof certificate for verification, and qualification documents ship with the goods. We will not pass off a cabinet without the proper certification as an explosion-proof cabinet.

How are operator components made explosion-proof?

Handles, pushbuttons and indicator lights are all explosion-proof types, and cable entries use explosion-proof cable glands. For operation in a hazardous area, ordinary components are a potential ignition source and cannot be used.

What applications suit pressurized (Ex p) protection?

Pressurized protection maintains positive pressure by supplying air to isolate hazardous gas, making it suitable for control cabinets with high capacity and many internal components. It is commonly used for high-capacity control and for locations requiring frequent maintenance.

What do you need for a quote?

Hazardous area classification, gas group, temperature class, control functions (start/stop, interlock, PLC, variable frequency drive), number of circuits and component requirements, installation environment. A hazardous area classification drawing is preferred.

09 — RELATED

Other cabinet types in the same main circuit

Related products use color-block placeholders for now (product photos not yet complete; they will be replaced together). Internal links will be filled in once live URLs are confirmed.

10 — RFQ

Need control in a hazardous environment? Confirm the explosion-proof type and certification first

Send us your hazardous area classification, gas group and control functions, and we will provide a free explosion-proof control cabinet solution · quotation within 24 hours. Direct from the source factory, MOQ 1 unit, 15–25 day delivery, 1-year warranty.

Email your inquiry WhatsApp: +86 186 5712 0011
GU ELECTRIC (Zhejiang Golden Unicorn) · 5,000 sqm workshop, Fengchuan Industrial Zone, Tonglu · 20 people · 5,800+ units per year
ISO 9001:2015 · CE(LVD+EMC) · CQC · IP65

When you write, include: single-line diagram or primary scheme, switch room layout, load list, and component brand requirements. You do not need complete drawings — capacity and cabinet type are enough to start.

Explosion-proof control cabinet · MOQ 1 unit · 15–25 days Get a quote