GU ELECTRIC — Beyond the CabinetGU ELECTRIC — Beyond the Cabinet Get a quote
Home/Products/Enclosures & Boxes/Carbon steel enclosures
B U I L D T O D R A W I N G Carbon steel cabinet, full front view (door with display and indicator lights)
PRODUCT — 03 · Enclosures & Boxes

Carbon steel enclosures

One sheet of cold-rolled steel, folded into the skeleton of a cabinet
Model GU-EN-CS · SPCC cold-rolled steel 1.2–2.0 mm · Width 400–1200 mm · MOQ 1 unit
The carbon steel enclosure is the most common enclosure format for control cabinets and distribution cabinets: 1.2–2.0 mm Baosteel / Ansteel cold-rolled steel (SPCC), CNC-bent, fully welded or riveted, then run through a nine-station degreasing–pickling–phosphating–surface conditioning pretreatment before electrostatic powder coating. Standard indoor color is RAL7035; outdoor versions can be hot-dip galvanized with a dual-coat system. It offers the best balance of structural strength, cost and processing lead time, and it is the highest-volume enclosure type in our shop — we can ship it as an empty white enclosure, with mounting rails and base plate, or as a fully assembled cabinet, depending on the project.
  • Sheet material: Baosteel / Ansteel SPCC cold-rolled steel 1.2–2.0 mm; frame uprights can be thickened to 2.5 mm
  • Structure: CNC-bent one-piece uprights + welded frame, cabinet diagonal tolerance ≤2 mm
  • Surface: degreasing–pickling–phosphating pretreatment + electrostatic powder coating, film thickness 60–80 μm
  • Protection: IP54 standard / IP65 optional (GB 4208 / IEC 60529); outdoor versions add a rain canopy
  • Shipping format: empty white enclosure / with mounting rails and base plate / fully assembled with components — per project
1.2–2.0 mmSPCC cold-rolled steel
≤2 mmCabinet diagonal tolerance
60–80 μmCoating film thickness
1 unitMOQ 1 unit · ≥5 recommended for volume production
01 — SPECIFICATION

Specifications

The table below covers 80% of factory distribution room cases. Anything outside it we can still build — those are engineered items, quoted separately, with an indicative price the same day.

Standard sizes (W×D×H)600×600×1200 / 600×600×1600 / 800×600×1800 / 800×800×2000 mm, non-standard available
Sheet thicknessDoor 1.5 mm / side panels 1.5 mm / mounting rails 2.0 mm / frame uprights 2.0–2.5 mm
Enclosure constructionCNC-bent welded frame + removable side panels / top panel, front and rear doors
Surface treatmentDegreasing–pickling–phosphating–surface conditioning nine-station pretreatment, electrostatic powder coating RAL7035 (outdoor: hot-dip galvanized + dual-coat system)
IP ratingIP54 standard / IP65 optional (GB 4208 / IEC 60529)
Mounting rail25 mm modular hole spacing; galvanized or painted finish available
Door and lockSingle or double door, three-point interlocking lock, polyurethane foam gasket
Cable entryBottom knockouts / pre-punched holes to drawing; gland plate optional
Rated load capacityUniformly distributed load on mounting rails ≤200 kg (total cabinet load capacity ≤400 kg)
Door load capacityWhen heavy components such as VFDs are door-mounted, add door support hinges based on weight
Electrical installationGrounding bar reserved (main grounding point ≥M6) and N bar mounting position
Internal partitioningVertical divider panels can be added for main control separation, per drawing
Thermal management provisionsTop fan position / louvers / air conditioner mounting position configured per drawing
Outdoor accessoriesRain hood, sun shield layer, bottom rodent mesh
Empty cabinet, unpainted bodyCustomer installs components; we supply cabinet + mounting rails + seals
Shipped with mounting hardware installedMounting rails, base plate, grounding bar, gland plate installed per drawing
Fully assembled cabinetCombined with ①② series control / distribution solutions and delivered as a complete cabinet
Outdoor typeHot-dip galvanized + dual coating + rain hood; 10-year outdoor coating warranty statement
Custom buildNon-standard dimensions, special cutouts, stainless steel liner machined to drawing
Structural standardGB/T 7251.1 / IEC 61439-1 (mechanical structure section)
Sheet material standardGB/T 708 cold-rolled steel sheet thickness and permissible tolerances
Coating standardGB/T 1732 paint film impact resistance, GB/T 9286 adhesion (Grade 1 target)
Factory inspection (per unit)Diagonal error, door gap uniformity, gasket compression, mounting rail hole position spot check
Documents with shipmentDimensional drawing, cutout drawing, material certificate (sheet heat lot number traceable)
02 — CONFIGURATOR

Five steps to specify your run

A configuration summary is generated as you go. It travels with your inquiry, saving a round of confirmation.

01Cabinet size
02Sheet thickness
03Surface treatment
04IP rating
05Options (multiple)
03 — CRAFT

Build details

Systems have been in service for decades, and the failure points are always the same few: poor busbar contact, water ingress at the door seal, high temperature rise in the correction cabinet, and mis-phased outgoing feeders. The six hard rules below are written for exactly these points — every cabinet can be traced to them.

CNC bending

One-piece formed corner post

The corner post is formed in a single pass on a CNC press brake, with no spliced weld seams — rigidity comes from the structure, not from weld points. This is the first process to inspect on an empty enclosure.

Full-seam welding and grinding

Weld seams that do not catch your hand

Frame corners are fully welded and ground point by point, so there is no weld spatter or burr to the touch; after coating, no visible depressions remain at the weld seams.

Nine-stage pretreatment

Half of coating life is decided before coating

Nine-stage tank pretreatment — degreasing, pickling, phosphating and conditioning — removes oil and oxide before coating, which is what gives the coating its adhesion (target: GB/T 9286 Class 1).

Modular-hole mounting rails

25 mm pitch

Mounting rails have a 25 mm hole pitch, so component positions can be adjusted on site — a design change does not mean re-drilling.

Foam gasket

Uniform door gap compression

The door frame gasket is a continuous one-piece polyurethane foam seal with no breaks, and the three-point latch pulls the door shut evenly — that is what makes an IP54/IP65 rating hold up.

Diagonal tolerance ≤2 mm

Cabinets that stand square

Cabinet diagonal error is checked on every unit. Out-of-tolerance cabinets produce crooked seams when lined up on site — this item does not pass inspection, so it does not ship.

04 — EVIDENCE

Photos & enclosure construction

Below are photos taken in our own shop — from the complete unit down to the internal busbars and secondary wiring. Every build detail can be checked item by item.

Carbon steel cabinet, full front view (door with display and indicator lights)
Carbon steel cabinet, full front view (door with display and indicator lights)
Stainless steel AK box · Photo 01
Stainless steel AK box · Photo 01
Stainless steel AK box · Photo 02
Stainless steel AK box · Photo 02
FRONT VIEW Power meter Status indication Channel base at the bottom · inter-cabinet busbars run through H 2200 W 800 / 1000 / 1200 IP54 standard IP65 optional Ue 400V ≤2000A Icw 30–65kA
Verifiable build checklist:2.0 mm seam-welded enclosure · diagonal ≤1.5 mm · busbar torqued to 30-40 N·m with witness marks · busbar joint temperature rise ≤70 K · segregated wiring compartments · CTs and meters in separate compartments · 60-80 μm coating · 2500 V/1 min withstand on every unit.

Image key: 01–05 are shop photos (the numbers match the shot list). The line drawing shows the front elevation of the enclosure; dimensions match the specification table above.

05 — APPLICATIONS

Where these cabinets go

These are the routine applications — we can talk scheme and configuration directly. For the industry view, see the industry pages.

Control cabinet enclosure

Empty white-body enclosure for PLC / VFD panels; the customer installs components, or we supply it assembled.

Distribution cabinet enclosure

Enclosure fabrication for site distribution and building main boxes, punched to GGD / XL-21 configurations.

Re-shelling old cabinets

For retrofit projects where the internals are still good but the enclosure is corroded, we build a new cabinet to the original component layout.

Equipment guards

Machine guards and isolation screens for production lines, custom sheet metal built to drawing.

Outdoor enclosures

For outdoor locations such as pump houses and telecom base stations: hot-dip galvanized + dual coating + rain hood.

Volume OEM supply

Enclosures supplied with equipment makers' batch orders, punched and painted to drawing; volume pricing quoted separately.

06 — TERMS

Commercial terms

Specification dated September 2026; quotations follow this.

Drawings & designFree
MOQ1 unit (5 or more recommended for production)
Production lead time15-25 days after drawing approval
on-time delivery98%
Warranty12 months
Loading portNingbo / Shanghai, China
Sheet steelBaosteel / Ansteel cold-rolled sheet (SPCC) / 304 stainless steel
Factory visit & dispatch confirmationFactory visits welcome; finished-cabinet photos and video before dispatch
Capacity5,800+ units / year
07 — DOWNLOADS

Documents for your engineering team

Selection manual, outline dimensions and RFQ checklist — for the customer's electrical engineer. All three documents are being organized by product line; download links go live once complete.

PDFSelection and configuration manualTechnical highlights, specifications, typical solutions and commercial termsIn progress · pending
DXFCommon outline & cut-out dimensionsFront view / side view / foundation and cable entry cutoutsIn progress · pending
XLSRFQ data checklistInformation to confirm before quoting — fill in and send backIn progress · pending
08 — FAQ

Six questions procurement and electrical engineers ask most

Is the price difference between an empty enclosure and one with mounting accessories significant?

Mounting rails, base plates and grounding bars are standard accessories; adding them all comes to within about 20% of the enclosure price. For a fully assembled cabinet with components, we quote per the Group ①② complete-cabinet options. Send us your list and we will quote both on the same basis for comparison.

How do I choose between cold-rolled and galvanized sheet?

For dry indoor environments, cold-rolled sheet with paint is sufficient. For damp, condensing or mildly corrosive environments, specify galvanized sheet as the base material, then paint. For severe outdoor corrosion (coastal or chemical plant areas), we recommend going straight to 304 stainless steel or hot-dip galvanizing + dual coating.

Is a 1.5 mm door panel thick enough?

For doors carrying only pushbuttons and meters, 1.5 mm is sufficient. If a VFD, HMI or other heavy component is mounted on the door, we recommend 2.0 mm with support hinges, and the load rating recalculated.

Can you build to my existing drawings?

Yes. Send DXF / PDF drawings for a quote. Please mark sheet thickness, inside bend radius, hole dimensions and tolerances. For volume orders, production starts after first-article approval.

How many years will the outdoor coating last?

Hot-dip galvanizing + dual coating (epoxy primer + polyester topcoat) is controlled to a 10-year coating integrity basis under normal outdoor atmospheric exposure. For coastal and chemical plant areas we recommend stainless steel and a reduced warranty expectation — we will tell you that straight.

Can enclosure lead time be faster than 15 days?

Standard-size empty enclosures are stocked as semi-finished frames, with the fastest lead time of 7–10 days. Non-standard sizes and special coatings run the full process at 15–25 days. In peak season, the lead time confirmed after drawing approval governs.

09 — RELATED

Other cabinet types in the same main circuit

Related products use color-block placeholders for now (product photos not yet complete; they will be replaced together). Internal links will be filled in once live URLs are confirmed.

10 — RFQ

Send your drawing or dimensions — empty enclosure quoted the same day

Send DXF / PDF drawings or overall dimensions and we will provide an enclosure plan and quote free of charge · reply within 24 hours · build-to-drawing customization supported. Direct from the source factory, MOQ 1 unit, 15–25 day delivery, 1-year warranty.

Email your inquiry WhatsApp: +86 186 5712 0011
GU ELECTRIC (Zhejiang Golden Unicorn) · 5,000 sqm workshop, Fengchuan Industrial Zone, Tonglu · 20 people · 5,800+ units per year
ISO 9001:2015 · CE(LVD+EMC) · CQC · IP65

When you write, include: single-line diagram or primary scheme, switch room layout, load list, and component brand requirements. You do not need complete drawings — capacity and cabinet type are enough to start.

Carbon Steel Enclosures · MOQ 1 unit · 15–25 days Get a quote