B U I L D T O D R A W I N G Autotransformer Reduced-Voltage Starter Cabinet · Photo 01
PRODUCT — 01 · Control & Automation Cabinets

Auto-transformer starter cabinets

Heavy loads get moving — without dragging the grid down
Model GU-AT · AC 380V · 15–315 kW · 65%/80% taps · MOQ 1 unit
The autotransformer reduced-voltage starter steps voltage down through autotransformer taps to start the motor. With 65%/80% taps, the 80% tap delivers up to 64% of full-voltage starting torque — nearly double the 1/3 available from star-delta — making it suitable for equipment that must start under load, such as ball mills, crushers and reciprocating compressors. Once starting is complete, the transformer is automatically cut out and the motor runs at full voltage; the transformer carries no current in run mode and consumes no extra power.
  • Autotransformer: 65% / 80% taps, dry-type (standard) or oil-immersed (high power, outdoor)
  • Starting torque: about 64% of full torque on the 80% tap, about 42% on the 65% tap — select the tap against the load resisting torque
  • Starting current: about 0.64 × direct-on-line current on the 80% tap, measured at the transformer primary
  • Settings: starting time adjustable 10–60 s; the overcurrent relay also provides transformer overload protection
  • Components: Schneider / ABB / Siemens / Chint; brand can be specified, or customer-supplied components shipped to our plant
64%Starting torque on the 80% tap
15–315 kWCommon power range
10–60 sAdjustable starting time
1 unitMOQ 1 unit · ≥5 recommended for volume production
01 — SPECIFICATION

Specifications

The table below covers 80% of factory distribution room cases. Anything outside it we can still build — those are engineered items, quoted separately, with an indicative price the same day.

TypeFloor-standing; starter and transformer can share one cabinet or be split (split recommended at ≥160 kW)
Standard sizes (W×D×H)800×600×1800 / 1000×800×2000 mm, sized by transformer capacity, custom build available
Enclosure construction2.0 mm cold-rolled carbon steel, separate transformer and electrical compartments, ventilation louvers
IP ratingIP54 standard / IP65 or outdoor type optional
Transformer mountingBottom channel steel load-bearing with vibration pads; oil-immersed transformer per site conditions
Cable entryBottom cable entry, busbar outgoing to the motor
Rated operating voltageAC 380V / 400V, 50 Hz; control circuit AC 220V
Applicable Power15–315 kW; choose this cabinet type first for heavy-duty starting
autotransformerQZB dry-type (standard) / oil-immersed (outdoor, high power), 65% / 80% taps
Transition methodTime relay 10–60 s automatic transfer; step-down power is cut before full voltage is applied (closed transition optional)
Protection configurationOvercurrent relay (transformer side) + thermal overload relay (running side); phase loss and overload
Metering and indicationAmmeter / voltmeter; step-down starting / full-voltage running / fault indication
Component brandsSchneider / ABB / Siemens / Chint; customer-supplied components accepted for factory installation
Open transition, standardMomentary power loss at transfer, then full voltage is applied; simple design, most widely used
Closed transitionNo power interruption at transfer, lower surge; suited to interlocked duty where even a momentary loss of supply is not acceptable
Compared with star-deltaChoose autotransformer starting for heavy loads (higher torque); choose star-delta for light loads (lower cost)
Compared with soft startOn a limited budget with single-speed operation, choose autotransformer starting; if you need an adjustable current ramp, choose a soft starter cabinet
Multiple motors from one unitOne autotransformer cabinet starts several motors in sequence (interlocked timing control), reducing total investment
Assembly standardGB/T 7251.1 / IEC 61439-1
Transformer testingWinding DC resistance, turns ratio and insulation resistance reports supplied with the unit
Routine tests (every unit)Insulation resistance, power-frequency withstand voltage, and a full powered start-transfer sequence run twice with currents recorded
Temperature riseTransformer temperature rise at full load is verified to its insulation class; terminal connections ≤70 K
Documents with shipmentSchematic diagram, terminal list, BOM, transformer and complete-cabinet test reports
02 — CONFIGURATOR

Five steps to specify your run

A configuration summary is generated as you go. It travels with your inquiry, saving a round of confirmation.

01Motor power
02Tap selection
03Transition method
04Component brands
05Options (multiple)
03 — CRAFT

Build details

Systems have been in service for decades, and the failure points are always the same few: poor busbar contact, water ingress at the door seal, high temperature rise in the correction cabinet, and mis-phased outgoing feeders. The six hard rules below are written for exactly these points — every cabinet can be traced to them.

64%

Torque Tap Calculated for Your Application

Before startup, we calculate the load resistance torque curve and specify the 80% or 65% tap in the proposal — no trial and error on site.

Separate Compartments for Heat Dissipation

Dedicated Transformer Compartment

The transformer is compartmentalized away from contactors and relays, each with its own air path, so hot air does not bake components and accelerate aging.

2 Cycles

Unit-by-Unit Energized Start Test

Each unit undergoes 2 complete reduced-voltage start transitions at the factory, with current waveforms recorded to verify transition timing and protection settings.

Load Bearing and Vibration Damping

Transformer Base Channel Steel

Transformer weight is transferred through bottom channel steel with vibration damping pads — neither transport nor operation relies on the side panels for structural support.

Tap Identification

Permanent Terminal Labels

The 65%/80% tap terminals carry permanent labels for instant identification during maintenance, eliminating wrong-tap connections.

Wiring Matches the Drawing

Wire Number = Circuit Number

All conductors are fitted with wire number sleeves matching the circuit numbers on the schematic. Delivery includes the complete schematic and terminal list.

04 — EVIDENCE

Photos & enclosure construction

Below are photos taken in our own shop — from the complete unit down to the internal busbars and secondary wiring. Every build detail can be checked item by item.

Autotransformer Reduced-Voltage Starter Cabinet · Photo 01
Carbon Steel Double-Door Control Cabinet · Photo 01
Autotransformer Reduced-Voltage Starter Cabinet · Photo 02
Carbon Steel Double-Door Control Cabinet · Photo 02
Autotransformer Reduced-Voltage Starter Cabinet · Photo 03
Carbon Steel Large Equipment Control Cabinet 2 · Photo 03
FRONT VIEW Power meter Status indication Channel base at the bottom · inter-cabinet busbars run through H 2200 W 800 / 1000 / 1200 IP54 standard IP65 optional Ue 400V ≤2000A Icw 30–65kA
Verifiable build checklist:2.0 mm seam-welded enclosure · diagonal ≤1.5 mm · busbar torqued to 30-40 N·m with witness marks · busbar joint temperature rise ≤70 K · segregated wiring compartments · CTs and meters in separate compartments · 60-80 μm coating · 2500 V/1 min withstand on every unit.

Image key: 01–05 are shop photos (the numbers match the shot list). The line drawing shows the front elevation of the enclosure; dimensions match the specification table above.

05 — APPLICATIONS

Where these cabinets go

These are the routine applications — we can talk scheme and configuration directly. For the industry view, see the industry pages.

Ball Mills and Grinding Equipment

Typical loaded-start scenario; the 80% tap torque covers static resistance torque.

Crushers

Jaw or impact crushers starting with a loaded cavity still require high initial torque — autotransformer starting is preferred.

Reciprocating Compressors

For start-under-pressure conditions, the tap position is calculated based on unloading capability.

High-Power Centrifugal Fans

Started with the damper closed; where grid capacity is insufficient, the 65% tap reduces inrush.

Deep Well Pumps and Line Shaft Pumps

High static head means high resistance — we size the tap after calculating starting torque.

Replacement for legacy XJ01 cabinets

We can also keep the existing transformer and replace only the control section — send site photos and we will issue a retrofit plan.

06 — TERMS

Commercial terms

Specification dated September 2026; quotations follow this.

Drawings & designFree
MOQ1 unit (5 or more recommended for production)
Production lead time15-25 days after drawing approval
on-time delivery98%
Warranty12 months
Loading portNingbo / Shanghai, China
Component brandsSchneider / ABB / Siemens / Chint
Factory visit & dispatch confirmationFactory visits welcome; finished-cabinet photos and video before dispatch
Capacity5,800+ units / year
07 — DOWNLOADS

Documents for your engineering team

Selection manual, outline dimensions and RFQ checklist — for the customer's electrical engineer. All three documents are being organized by product line; download links go live once complete.

PDFSelection and configuration manualTechnical highlights, specifications, typical solutions and commercial termsIn progress · pending
DXFCommon outline & cut-out dimensionsFront view / side view / foundation and cable entry cutoutsIn progress · pending
XLSRFQ data checklistInformation to confirm before quoting — fill in and send backIn progress · pending
08 — FAQ

Six questions procurement and electrical engineers ask most

What actually separates autotransformer starting from star-delta?

Torque: star-delta delivers only 1/3 of full-voltage starting torque; the 80% tap on an autotransformer gives about 64%. For heavy-load starting, autotransformer is the only option. Motor compatibility: star-delta works only with delta-connected motors; autotransformer works with any connection. Cost: autotransformer adds a transformer and runs 30–50% more. Light load — choose star-delta. Heavy load — choose autotransformer.

65% tap or 80% tap?

80% is the default: 64% torque, enough to start most heavy loads, with current at about 64% of direct-on-line. Choose 65% where the grid is weak, transformer capacity is small, or voltage dip is a concern (42% current, but torque also drops to 42% — the load resistance torque must be checked). If you are unsure, tell us the load type and we will run the starting calculation free of charge.

Dry-type or oil-immersed transformer?

For typical indoor installations, dry-type (QZB) — simple maintenance, no oil contamination. For outdoor or high-power duty (≥200 kW), oil-immersed is an option: better heat dissipation, but site fire protection requirements apply. We supply dry-type by default; oil-immersed is quoted per project.

How many consecutive starts are allowed?

The autotransformer is rated for short-time duty and will overheat under consecutive starts. As a rule of thumb, no more than 2 consecutive starts from cold; further starts require a cooling interval (about 30 minutes or more). For frequent starting duty (multiple starts per hour), use a soft starter cabinet or VFD panel instead — thyristors do not have this limitation.

What about 315 kW and above?

For high-power heavy loads, we recommend evaluating a soft starter cabinet (thyristor current-limit ramp) or a medium voltage switchgear solution directly; above 315 kW the transformer size and cost of an autotransformer scheme no longer make sense. Send us the motor data and duty conditions and we will provide a comparison.

Does the transfer cause a power interruption?

Open transition interrupts power briefly (tens of milliseconds) before applying full voltage — imperceptible to most equipment. Closed transition bridges with a third contactor, so there is no interruption and lower current surge; choose it for interlock-sensitive duty.

09 — RELATED

Other cabinet types in the same main circuit

Related products use color-block placeholders for now (product photos not yet complete; they will be replaced together). Internal links will be filled in once live URLs are confirmed.

10 — RFQ

Heavy-load starting calculation, free of charge

Send us the motor nameplate and load type (ball mill / crusher / fan) and we will calculate starting torque and specify the tap free of charge · quotation within 24 hours. Direct from the source factory, MOQ 1 unit, 15–25 day delivery, 1-year warranty.

Email your inquiry WhatsApp: +86 186 5712 0011
GU ELECTRIC (Zhejiang Golden Unicorn) · 5,000 sqm workshop, Fengchuan Industrial Zone, Tonglu · 20 people · 5,800+ units per year
ISO 9001:2015 · CE(LVD+EMC) · CQC · IP65

When you write, include: single-line diagram or primary scheme, switch room layout, load list, and component brand requirements. You do not need complete drawings — capacity and cabinet type are enough to start.

Autotransformer reduced-voltage starter cabinet · MOQ 1 unit · 15–25 days Get a quote